Required Loads per
Simpson Catalog Form C-ATS05 Expires 1/31/07 |
2003 IBC Runs |
|
|
1997 UBC Runs |
|
|
|
CAT 5-6HS8HS (T52) |
|
Reqd |
Tension |
Diff. |
Level |
Load |
Load |
Load |
|
lbs |
Rod |
Plate |
5 |
7,850 |
17,672 |
17,600 |
|
|
R6HS |
S19 |
4 |
12,270 |
17,652 |
|
|
|
R6HS |
|
3 |
17,600 |
17,672 |
|
|
|
R6HS |
|
2 |
24,050 |
31,416 |
13,810 |
|
|
R8HS |
S14 |
1 |
31,410 |
31,416 |
|
|
|
R8HS |
|
|
|
CAT 5-6HS8HS (T52)
Details Page
Under Construction
Contact Us
for further
Information |
|
|
|
CAT 5-6HS8HS (T52) |
|
Reqd |
Tension |
Diff. |
Level |
Load |
Load |
Load |
|
lbs |
Rod |
Plate |
5 |
10,400 |
23,563 |
23,560 |
|
|
R6HS |
S24 |
4 |
16,360 |
23,563 |
|
|
|
R6HS |
|
3 |
23,560 |
23,563 |
|
|
|
R6HS |
|
2 |
32,070 |
41,888 |
18,320 |
|
|
R8HS |
S19 |
1 |
41,880 |
41,888 |
|
|
|
R8HS |
|
|
|
CAT 5-6HS8HS (T52)
Details Page
Under Construction
Contact Us
for further
Information |
Two Take-Up Device Equivalent |
|
|
Two Take-Up Device Equivalent |
|
|
|
|
|
CAT 5-66HS7HS8HS (T54321) |
|
|
Reqd |
Tension |
Diff. |
Level |
Load |
Load |
Load |
|
lbs |
Rod |
Plate |
5 |
7,850 |
8,836 |
7,850 |
|
|
R6 |
S8 |
4 |
12,270 |
17,672 |
4,420 |
|
|
R6HS |
S8 |
3 |
17,600 |
17,672 |
5,330 |
|
|
R6HS |
S8 |
2 |
24,050 |
24,053 |
6,450 |
|
|
R7HS |
S8 |
1 |
31,410 |
31,416 |
7,360 |
|
|
R8HS |
S8 |
|
|
CAT 5-66HS7HS8HS
(T54321)
Details Page
Under Construction
Contact Us
for further
Information |
|
|
|
CAT 5-66HS7HS8HS (T54321) |
|
|
Reqd |
Tension |
Diff. |
Level |
Load |
Load |
Load |
|
lbs |
Rod |
Plate |
5 |
10,400 |
11,781 |
10,400 |
|
|
R6HS |
S10 |
4 |
16,360 |
23,563 |
5,960 |
|
|
R6HS |
S8 |
3 |
23,560 |
23,563 |
7,200 |
|
|
R6HS |
S8 |
2 |
32,070 |
32,070 |
8,510 |
|
|
R7HS |
S8 |
1 |
41,880 |
41,888 |
9,810 |
|
|
R8HS |
S10 |
|
|
CAT 5-66HS7HS8HS (T54321)
Details Page
Under Construction
Contact Us
for further
Information |
Take-Up Device Every Level
Required by Many Structural Plans |
|
|
Take-Up Device Every Level
Required by the City of San Diego |
Embedments
(under construction) |
|
|
Compression Trimmers
Douglas Fir-Larch
Hem-Fir
|
|
Contact
Webmaster with questions
or comments |
Copyright 2005
Commins Manufacturing, Inc., Friday Harbor, WA 98250, Tel (360) 378-9484 |
|
AutoTight® Rod Holdown Systems and components are covered by one or more
of the following U.S. Patents 6,390,747; 6,585,469; 6,625,945, other
patents both foreign and domestic are pending. |
|