Compression Trimmer
Table - Hem-Fir |
Douglas Fir - Larch |
Hem - Fir |
6" Walls
(Number) |
Trimmer |
Comp. Perp Grain |
Parallel to Grain, Pc
Lbs (133) |
|
Size |
HF @ 405 psi |
8' |
9' |
10' |
11' |
12' |
|
|
Per Each |
Per Pair (Each Side of Rod) |
1 |
2 x 6 |
3,341 |
6,683 |
13,675 |
12,133 |
10,609 |
9,218 |
8,008 |
1 |
3 x 6 |
5,569 |
11,138 |
30,380 |
25,472
|
21,376
|
18,059
|
15,392
|
1 |
4 x 6 |
7,796 |
15,593 |
47,222 |
40,054
|
33,869
|
28,755
|
24,589
|
1 |
6 x 6 |
12,251 |
24,503 |
52,142 |
46,693
|
41,150
|
35,968
|
31,380
|
1 |
6 x 8 |
16,706 |
33,413 |
71,103 |
63,672
|
56,114
|
49,048
|
42,792
|
1 |
6 x 10 |
21,161 |
42,323 |
90,064 |
80,652
|
71,078
|
62,127
|
54,203
|
1 |
6 x 12 |
25,616 |
51,233 |
109,025 |
97,631
|
86,041
|
75,207
|
65,614
|
2 |
2 x 6 |
6,683 |
13,365 |
27,351 |
24,267 |
21,218 |
18,436 |
16,016 |
3 |
2 x 6 |
10,024 |
20,048 |
41,027 |
36,401
|
31,827
|
27,654
|
24,025
|
4 |
2 x 6 |
13,365 |
26,730 |
53,136 |
47,459
|
41,729
|
36,411
|
31,727
|
5 |
2 x 6 |
16,706 |
33,413 |
66,420 |
59,323
|
52,162
|
45,514
|
39,659
|
6 |
2 x 6 |
20,048 |
40,095 |
79,705 |
71,188
|
62,594
|
54,617
|
47,591
|
7 |
2 x 6 |
23,389 |
46,778 |
92,989 |
83,053
|
73,027
|
63,720
|
55,523
|
|
|
|
Normal |
Connection Limited by Parallel to Grain Load |
|
|
|
Limit |
|
|
|
|
|
|
|
4" Walls
(Number) |
Trimmer |
Comp. Perp Grain |
Parallel to Grain, Pc
Lbs (133) |
|
Size |
HF @ 405 psi |
8' |
9' |
10' |
11' |
12' |
|
|
Per Each |
Per Pair (Each Side of Rod) |
1 |
2 x 4 |
2,126 |
4,253 |
4,849 |
3,928 |
3,226 |
2,689 |
2,270 |
1 |
3 x 4 |
3,938 |
7,875 |
9,308 |
7,405 |
6,016 |
4,977 |
4,182 |
1 |
4 x 4 |
4,961 |
9,923 |
14,893 |
11,880
|
9,668 |
8,007 |
6,733 |
1 |
4 x 6 |
7,796 |
15,593 |
23,298 |
18,609
|
15,156
|
12,559
|
10,565
|
1 |
4 x 8 |
10,631 |
21,263 |
30,557 |
24,443
|
19,926
|
16,521
|
13,904
|
1 |
4 x 10 |
13,466 |
26,933 |
38,768 |
31,062
|
25,347
|
21,030
|
17,707
|
1 |
4 x 12 |
16,301 |
32,603 |
47,150 |
37,779
|
30,827
|
25,577
|
21,535
|
2 |
2 x 4 |
4,253 |
8,505 |
9,699 |
7,856 |
6,453 |
5,378 |
4,541 |
3 |
2 x 4 |
6,379 |
12,758 |
14,549 |
11,785
|
9,680 |
8,067 |
6,812 |
4 |
2 x 4 |
8,505 |
17,010 |
19,399 |
15,713
|
12,907
|
10,756
|
9,083 |
5 |
2 x 4 |
10,631 |
21,263 |
24,249 |
19,642
|
16,134
|
13,445
|
11,353
|
6 |
2 x 4 |
12,758 |
25,515 |
29,099 |
23,570
|
19,361
|
16,134
|
13,624
|
7 |
2 x 4 |
14,884 |
29,768 |
33,949 |
27,499
|
22,588
|
18,823
|
15,895
|
|
|
|
Normal |
Connection Limited by Parallel to Grain Load |
|
|
|
Limit |
|
|
|
|
|
|
Download -
Hem-Fir
Trimmer Table. pdf
- (1 page, 13.0k) Acrobat Reader
is required to view the
material.
|
|